80 laporan ditemukan · 16 belum selesai
| NO | Tanggal / Petugas | Lokasi | Keterangan Aktivitas | Kondisi & Rekomendasi | Notifikasi | Dokumentasi | Status | Aksi |
|---|---|---|---|---|---|---|---|---|
| 1 |
07 Nov 2026
Anton Diki W
|
PHC-02
CIGADING 1
|
Pengukuran suhu ruang elektrik 30,2 derajat Celcius.
|
LAIK PAKAI
PREVENTIVE MAINTENANCE
|
TIDAK | Ready to Use |
||
| 2 |
07 Nov 2026
Anton Diki W
|
PHC-02
CIGADING 1
|
Pengukuran suhu ruang trafo 44,8 derajat Celcius.
|
LAIK PAKAI
PREVENTIVE MAINTENANCE
|
TIDAK | Ready to Use |
||
| 3 |
07 Nov 2026
Anton Diki W
|
PHC-02
CIGADING 1
|
Pengukuran suhu ruang gantry 42,1 derajat Celcius.
|
LAIK PAKAI
PREVENTIVE MAINTENANCE
|
TIDAK | Ready to Use |
||
| 4 |
07 Nov 2026
Anton Diki W
|
PHC-02
CIGADING 1
|
Inspeksi dan pengencangan baud di ruang panel elektrik
|
LAIK PAKAI
PREVENTIVE MAINTENANCE
|
TIDAK | Ready to Use |
||
| 5 |
07 Nov 2026
Anton Diki W
|
PHC-02
CIGADING 1
|
Dinding motor room di bagian merak ( dekat pintu ) ada yg bolong , request repair
|
LAIK PAKAI
REQUEST REPAIR
|
Low | Outstanding |
||
| 6 |
07 Nov 2026
Anton Diki W
|
PHC-02
CIGADING 1
|
Grounding area gantry terpantau terpasang semua PHC 02
|
LAIK PAKAI
PREVENTIVE MAINTENANCE
|
TIDAK | Ready to Use |
||
| 7 |
07 Nov 2026
Anton Diki W
|
PHC-02
CIGADING 1
|
Bridge crane PHC 02 kondisi OK
|
LAIK PAKAI
PREVENTIVE MAINTENANCE
|
TIDAK | Ready to Use |
||
| 8 |
07 Nov 2026
Anton Diki W
|
PHC-02
CIGADING 1
|
Cleaning motor kabel drum medium voltage PHC 02
|
LAIK PAKAI
PREVENTIVE MAINTENANCE
|
TIDAK | Ready to Use |
||
| 9 |
07 Nov 2026
Anton Diki W
|
PHC-02
CIGADING 1
|
Kondisi Slipring PHC 02 untuk saat ini masih terpantau amann
|
LAIK PAKAI
PREVENTIVE MAINTENANCE
|
TIDAK | Ready to Use |
||
| 10 |
07 Nov 2026
Anton Diki W
|
PHC-02
CIGADING 1
|
cleaning power pack break holding , closing dan luffing PHC 02
|
LAIK PAKAI
PREVENTIVE MAINTENANCE
|
TIDAK | Ready to Use |
||
| 11 |
07 Nov 2026
Anton Diki W
|
PHC-02
CIGADING 1
|
exhaust fan noise kasar req. service PHC 02
|
RUSAK RINGAN
REQUEST SERVICE
|
Medium 130000018901 |
In Process |
||
| 12 |
07 Nov 2026
Anton Diki W
|
PHC-02
CIGADING 1
|
Exhaust fan ruang trafo mati 1 sebelah anyer PHC 02
|
RUSAK RINGAN
REQUEST SERVICE
|
Medium 130000019291 |
In Process |
||
| 13 |
07 Nov 2026
Anton Diki W
|
PHC-02
CIGADING 1
|
Motor creeper No.3 sebalah darat anyer tidak terpasang req. Pasang , PHC 02
|
RUSAK RINGAN
PREVENTIVE MAINTENANCE
|
PANTAU | Ready to Use |
||
| 14 |
07 Nov 2026
Anton Diki W
|
PHC-02
CIGADING 1
|
Motor gantry No.5 sebalah darat merak tidak terpasang req. Pasang
PHC 02 |
RUSAK RINGAN
PREVENTIVE MAINTENANCE
|
PANTAU | Ready to Use |
||
| 15 |
07 Nov 2026
Anton Diki W
|
PHC-02
CIGADING 1
|
Cleaning motor powerpack gate Hooper dan panel powerpack gate Hooper PHC 02
|
LAIK PAKAI
PREVENTIVE MAINTENANCE
|
TIDAK | Ready to Use |
||
| 16 |
07 Nov 2026
Anton Diki W
|
PHC-02
CIGADING 1
|
Cleaning dan lubrikasi motor creeper gantry PHC 02
|
LAIK PAKAI
PREVENTIVE MAINTENANCE
|
TIDAK | Ready to Use |
||
| 17 |
26 Oct 2026
Anton Diki W
|
PHC-02
CIGADING 1
|
Pengukuran suhu ruang trafo 48 derajat Celcius
|
LAIK PAKAI
PREVENTIVE MAINTENANCE
|
TIDAK | Ready to Use |
||
| 18 |
26 Oct 2026
Anton Diki W
|
PHC-02
CIGADING 1
|
Pengukuran suhu ruang panel gantry 42 derajat Celcius
|
LAIK PAKAI
PREVENTIVE MAINTENANCE
|
TIDAK | Ready to Use |
||
| 19 |
26 Oct 2026
Anton Diki W
|
PHC-02
CIGADING 1
|
Pengukuran suhu motor PHC-02 :
HOLDING drive 42 Bearing 41 Fan 51 Brake 1 & 2 45 43 CLOSING Drive 48 Bearing 44 Fan 52 Brake 1 & 2 48 47 SLEWING 1 Drive 42 Bearing 40 Fan 41 Brake 45 SLEWING 2 Drive 47 Bearing 42 Fan 41 Brake 48 LUFFING Drive 39 Bearing 35 Fan 38 Brake 40 |
LAIK PAKAI
PREVENTIVE MAINTENANCE
|
TIDAK | Ready to Use |
||
| 20 |
26 Oct 2026
Anton Diki W
|
PHC-02
CIGADING 1
|
cleaning power pack break holding , closing dan luffing PHC 02
|
LAIK PAKAI
PREVENTIVE MAINTENANCE
|
TIDAK | Ready to Use |
||
| 21 |
26 Oct 2026
Anton Diki W
|
PHC-02
CIGADING 1
|
exhaust fan noise kasar req. service PHC 02
|
RUSAK RINGAN
REQUEST SERVICE
|
Medium 130000018901 |
In Process |
||
| 22 |
26 Oct 2026
Anton Diki W
|
PHC-02
CIGADING 1
|
Exhaust fan ruang trafo mati 1 sebelah anyer PHC 02
|
RUSAK RINGAN
REQUEST SERVICE
|
Medium 130000019291 |
In Process |
||
| 23 |
26 Oct 2026
Anton Diki W
|
PHC-02
CIGADING 1
|
Motor creeper No.3 sebalah darat anyer tidak terpasang req. Pasang , PHC 02
|
RUSAK RINGAN
REQUEST SERVICE
|
Medium | Outstanding |
||
| 24 |
26 Oct 2026
Anton Diki W
|
PHC-02
CIGADING 1
|
Motor gantry No.5 sebelah darat merak tidak terpasang req. Pasang
PHC 02 |
RUSAK RINGAN
REQUEST SERVICE
|
Medium | Outstanding |
||
| 25 |
26 Oct 2026
Anton Diki W
|
PHC-02
CIGADING 1
|
Kondisi Slipring PHC 02 terpantau OK
|
LAIK PAKAI
PREVENTIVE MAINTENANCE
|
TIDAK | Ready to Use |
||
| 26 |
26 Oct 2026
Anton Diki W
|
PHC-02
CIGADING 1
|
Cleaning motor powerpack gate Hooper dan panel powerpack gate Hooper PHC 02 before dan after
|
LAIK PAKAI
PREVENTIVE MAINTENANCE
|
TIDAK | Ready to Use |
||
| 27 |
26 Oct 2026
Anton Diki W
|
PHC-02
CIGADING 1
|
Cleaning motor creeper gantry PHC 02
|
LAIK PAKAI
PREVENTIVE MAINTENANCE
|
TIDAK | Ready to Use |
||
| 28 |
26 Oct 2026
Anton Diki W
|
PHC-02
CIGADING 1
|
Kabel power incoming Drive VSD Closed/gantry PHC-02 kabel power indikasi muai/terbakar. Suhu kabel 48 ⁰C sebelum panel di buka, setelah panel dibuka menjadi 40 ⁰C. Perbandingan dengan yang lain 30 ⁰C. Req.repair
Sudah di infokan ke. Cc-elektrik cg1 Pak haykal Mas suleman (Akan dilakukan perbaikan setelah bongkaran gandum selesai est.2 hari, sementara dilakukan pengecekan suhu secara berkala oleh elektrik shift) |
RELEASE
BY EXECUTOR
|
Medium 130000019292 |
Completed |
||
| 29 |
19 Oct 2026
Hasyim Alhabsyi
|
PHC-02
CIGADING 1
|
Pengukuran suhu ruang trafo PHC-02 saat Shutdown Inspection.
Hasil pengukuran berada di range normal. |
LAIK PAKAI
PREVENTIVE MAINTENANCE
|
TIDAK | Ready to Use |
||
| 30 |
19 Oct 2026
Hasyim Alhabsyi
|
PHC-02
CIGADING 1
|
Kondisi slipring PHC-02 terpantau aman
|
LAIK PAKAI
PREVENTIVE MAINTENANCE
|
TIDAK | Ready to Use |
||
| 31 |
19 Oct 2026
Hasyim Alhabsyi
|
PHC-02
CIGADING 1
|
Cleaning motorpowerpack gate hopper PHC-02
|
LAIK PAKAI
PREVENTIVE MAINTENANCE
|
TIDAK | Ready to Use |
||
| 32 |
08 Oct 2026
Hasyim Alhabsyi
|
PHC-02
CIGADING 1
|
Cleaning motor gantry PHC-02
|
LAIK PAKAI
PREVENTIVE MAINTENANCE
|
TIDAK | Ready to Use |
||
| 33 |
08 Oct 2026
Hasyim Alhabsyi
|
PHC-02
CIGADING 1
|
Hasil Megger Motor gantry phc-02 No. 7 sebelah darat, Oke
U1 - G : 550 Mohm V1 - G : 550 Mohm W1 - G : 550 Mohm U2 - G : 550 Mohm V2 - G : 550 Mohm W2 - G : 550 Mohm Antar Phase U1 - U2 : 0 Mohm U1 - V2 : 550 Mohm U1 - W2 : 550 Mohm V1 - V2 : 0 Mohm V1 - U2 : 550 Mohm V1 - W2 : 550 Mohm W1 - W2 : 0 Mohm W1 - U2 : 550 Mohm W1 - V2 : 550 Mohm |
LAIK PAKAI
PREVENTIVE MAINTENANCE
|
TIDAK | Ready to Use |
||
| 34 |
08 Oct 2026
Hasyim Alhabsyi
|
PHC-02
CIGADING 1
|
Hasil Megger Motor gantry phc-02 no 7 sebelah darat , Oke
U1 - G : 550 Mohm V1 - G : 550 Mohm W1 - G : 550 Mohm U2 - G : 550 Mohm V2 - G : 550 Mohm W2 - G : 550 Mohm Antar Phase U1 - U2 : 0 Mohm U1 - V2 : 550 Mohm U1 - W2 : 550 Mohm V1 - V2 : 0 Mohm V1 - U2 : 550 Mohm V1 - W2 : 550 Mohm W1 - W2 : 0 Mohm W1 - U2 : 550 Mohm W1 - V2 : 550 Mohm |
LAIK PAKAI
PREVENTIVE MAINTENANCE
|
TIDAK | Ready to Use |
||
| 35 |
08 Oct 2026
Anton Diki W
|
PHC-02
CIGADING 1
|
Hasil Megger Motor gantry phc-02 no 4 sebelah laut , Oke
U1 - G : 550 Mohm V1 - G : 550 Mohm W1 - G : 550 Mohm U2 - G : 550 Mohm V2 - G : 550 Mohm W2 - G : 550 Mohm Antar Phase U1 - U2 : 0 Mohm U1 - V2 : 550 Mohm U1 - W2 : 550 Mohm V1 - V2 : 0 Mohm V1 - U2 : 550 Mohm V1 - W2 : 550 Mohm W1 - W2 : 0 Mohm W1 - U2 : 550 Mohm W1 - V2 : 550 Mohm |
LAIK PAKAI
PREVENTIVE MAINTENANCE
|
TIDAK | Ready to Use |
||
| 36 |
08 Oct 2026
Anton Diki W
|
PHC-02
CIGADING 1
|
Hasil Megger Motor gantry phc-02 no 1 sebelah laut , Oke
U1 - G : 550 Mohm V1 - G : 550 Mohm W1 - G : 550 Mohm U2 - G : 550 Mohm V2 - G : 550 Mohm W2 - G : 550 Mohm Antar Phase U1 - U2 : 0 Mohm U1 - V2 : 550 Mohm U1 - W2 : 550 Mohm V1 - V2 : 0 Mohm V1 - U2 : 550 Mohm V1 - W2 : 550 Mohm W1 - W2 : 0 Mohm W1 - U2 : 550 Mohm W1 - V2 : 550 Mohm |
LAIK PAKAI
PREVENTIVE MAINTENANCE
|
TIDAK | Ready to Use |
||
| 37 |
08 Oct 2026
Anton Diki W
|
PHC-02
CIGADING 1
|
Hasil Megger Motor gantry phc-02 no 2 sebelah laut , Oke
U1 - G : 550 Mohm V1 - G : 550 Mohm W1 - G : 550 Mohm U2 - G : 550 Mohm V2 - G : 550 Mohm W2 - G : 550 Mohm Antar Phase U1 - U2 : 0 Mohm U1 - V2 : 550 Mohm U1 - W2 : 550 Mohm V1 - V2 : 0 Mohm V1 - U2 : 550 Mohm V1 - W2 : 550 Mohm W1 - W2 : 0 Mohm W1 - U2 : 550 Mohm W1 - V2 : 550 Mohm |
LAIK PAKAI
PREVENTIVE MAINTENANCE
|
TIDAK | Ready to Use |
||
| 38 |
09 Sep 2026
Hasyim Alhabsyi
|
PHC-02
CIGADING 1
|
Inspeksi dan Pengukuran suhu panel gantry PHC-02 : 38.8°C
|
LAIK PAKAI
PREVENTIVE MAINTENANCE
|
TIDAK | Ready to Use |
||
| 39 |
09 Sep 2026
Hasyim Alhabsyi
|
PHC-02
CIGADING 1
|
Inspeksi dan Pengukuran suhu trafo PHC-02 : 41.9°C
|
LAIK PAKAI
PREVENTIVE MAINTENANCE
|
TIDAK | Ready to Use |
||
| 40 |
09 Sep 2026
Hasyim Alhabsyi
|
PHC-02
CIGADING 1
|
Supporting elektrik eksekutor// Pemasangan kabel baru Medium Volatge 6KV di PHC-02
|
LAIK PAKAI
PREVENTIVE MAINTENANCE
|
TIDAK | Ready to Use |
||
| 41 |
08 Sep 2026
Anton Diki W
|
PHC-02
CIGADING 1
|
Motor kabel drum sebelah merak PHC-02 noise bearing kasar , couple macet pada saat di putar ke arah merak , request service
|
RUSAK RINGAN
REQUEST SERVICE
|
Medium 130000018946 |
In Process |
||
| 42 |
08 Sep 2026
Anton Diki W
|
PHC-02
CIGADING 1
|
Motor kabel drum sebelah anyer PHC-02 noise bearing kasar, request service
|
RELEASE
REQUEST SERVICE
|
Medium 130000018947 |
Completed |
||
| 43 |
08 Sep 2026
Anton Diki W
|
PHC-02
CIGADING 1
|
Motor cabel drum medium voltage PHC 02 sebelah merak hasil nilai 18,20Mohm ( no oke / tahanan kecil ) , request service
|
RUSAK RINGAN
REQUEST SERVICE
|
Medium 130000018948 |
In Process |
||
| 44 |
08 Sep 2026
Anton Diki W
|
PHC-02
CIGADING 1
|
Motor cabel drum medium voltage PHC 02 sebelah Anyer hasil nilai 3,25Mohm - 10,39Mohm ( no oke / tahanan kecil ) , request service
|
RELEASE
REQUEST SERVICE
|
Medium 130000018949 |
Completed |
||
| 45 |
05 Sep 2026
Anton Diki W
|
PHC-02
CIGADING 1
|
Pengukuran suhu motor PHC-02 :
HOLDING drive 40 Bearing 40 Fan 51 Brake 1 & 2 39 40 CLOSING Drive 41 Bearing 40 Fan 57 Brake 1 & 2 46 44 SLEWING 1 Drive 44 Bearing 38 Fan 46 Brake 43 SLEWING 2 Drive 42 Bearing 40 Fan 40 Brake 45 LUFFING Drive 34 Bearing 33 Fan 38 Brake 36 |
LAIK PAKAI
PREVENTIVE MAINTENANCE
|
TIDAK | Ready to Use |
||
| 46 |
05 Sep 2026
Anton Diki W
|
PHC-02
CIGADING 1
|
Inspeksi area slipring PHC-02 sudah mulai berdebu tebal. Req. service & cleaning
|
KOTOR
REQUEST SERVICE
|
Medium 130000018903 |
In Process |
||
| 47 |
05 Sep 2026
Anton Diki W
|
PHC-02
CIGADING 1
|
suhu trafo PHC-02
|
LAIK PAKAI
PREVENTIVE MAINTENANCE
|
TIDAK | Ready to Use |
||
| 48 |
05 Sep 2026
Anton Diki W
|
PHC-02
CIGADING 1
|
ruang trafo PHC-2 korosi bolong di bagian pojok laut dekat pintu
|
RELEASE
REQUEST REPAIR
|
Medium 130000018066 |
Completed |
||
| 49 |
05 Sep 2026
Anton Diki W
|
PHC-02
CIGADING 1
|
Inspeksi pada bagian Exhaust fan, terdapat noise kasar saat posisi running.
Req. Service |
RUSAK RINGAN
REQUEST SERVICE
|
Medium 130000018901 |
In Process |
||
| 50 |
05 Sep 2026
Anton Diki W
|
PHC-02
CIGADING 1
|
Inspeksi area top boom. Motor pin lock phc-02 tidak terpasang
|
RUSAK RINGAN
REQUEST GANTI
|
Medium 130000018902 |
In Process |