88 laporan ditemukan · 9 belum selesai
| NO | Tanggal / Petugas | Lokasi | Keterangan Aktivitas | Kondisi & Rekomendasi | Notifikasi | Dokumentasi | Status | Aksi |
|---|---|---|---|---|---|---|---|---|
| 1 |
21 Nov 2026
Anton Diki W
|
GSU-04
CIGADING 1
|
Pengukuran suhu Auxtrafo GSU-04
|
LAIK PAKAI
PREVENTIVE MAINTENANCE
|
TIDAK | Ready to Use |
||
| 2 |
21 Nov 2026
Anton Diki W
|
GSU-04
CIGADING 1
|
Pengukuran suhu main trafo GSU-04
|
LAIK PAKAI
PREVENTIVE MAINTENANCE
|
TIDAK | Ready to Use |
||
| 3 |
21 Nov 2026
Anton Diki W
|
GSU-04
CIGADING 1
|
Pengukuran suhu ruang elektrik GSU 04
|
LAIK PAKAI
PREVENTIVE MAINTENANCE
|
TIDAK | Ready to Use |
||
| 4 |
21 Nov 2026
Anton Diki W
|
GSU-04
CIGADING 1
|
Pengukuran suhu motor Gsu-04
Holding Drive 46 Bearing 38 Fan 45 Closing Drive 54 Bearing 40 Fan 45 Trolley Drive 52 Bearing 37 Fan 46 Suhu Motor belt feeder GSU 04 Drive 35 |
LAIK PAKAI
PREVENTIVE MAINTENANCE
|
TIDAK | Ready to Use |
||
| 5 |
21 Nov 2026
Anton Diki W
|
GSU-04
CIGADING 1
|
Motor drive closing terpantau Kotor di GSU 04 butuh di cleaning
|
KOTOR
REQUEST BERSIHKAN
|
Medium 130000019653 |
In Process |
||
| 6 |
21 Nov 2026
Anton Diki W
|
GSU-04
CIGADING 1
|
Main trafo GSU 04 butuh di cleaning
|
KOTOR
REQUEST BERSIHKAN
|
Medium 130000019652 |
In Process |
||
| 7 |
21 Nov 2026
Anton Diki W
|
GSU-04
CIGADING 1
|
Cleaning dan Penggantian filter motor fan holding closing trolley GSU-04
|
LAIK PAKAI
PREVENTIVE MAINTENANCE
|
TIDAK | Ready to Use |
||
| 8 |
21 Nov 2026
Anton Diki W
|
GSU-04
CIGADING 1
|
Lubrikasi roll festune cabin operator GSU 04
|
LAIK PAKAI
PREVENTIVE MAINTENANCE
|
TIDAK | Ready to Use |
||
| 9 |
21 Nov 2026
Anton Diki W
|
GSU-04
CIGADING 1
|
Menghidupkan jalur lampu yg mati di area boom GSU 04
Setelah di cek lampu yg mati hanya 1pcs di sebelah anyer |
RUSAK RINGAN
REQUEST GANTI
|
Medium 130000019651 |
In Process |
||
| 10 |
21 Nov 2026
Anton Diki W
|
GSU-04
CIGADING 1
|
Motor creeper gantry GSU 04 tidak 2pcs, 1pcs sebelah laut dan 1pcs sebelah darat
|
RUSAK RINGAN
PREVENTIVE MAINTENANCE
|
Medium 130000019650 |
In Process |
||
| 11 |
14 Nov 2026
Hasyim Alhabsyi
|
GSU-04
CIGADING 1
|
Pengukuran suhu motor belt feeder GSU-04 :
Drive 38,8 derajat celcius Bearing 37,8 derajat celcius |
LAIK PAKAI
PREVENTIVE MAINTENANCE
|
TIDAK | Ready to Use |
||
| 12 |
14 Nov 2026
Hasyim Alhabsyi
|
GSU-04
CIGADING 1
|
Lubrikasi zerospeed GSU-04
|
LAIK PAKAI
PREVENTIVE MAINTENANCE
|
TIDAK | Ready to Use |
||
| 13 |
11 Nov 2026
Anton Diki W
|
GSU-04
CIGADING 1
|
Pengukuran suhu trafo GSU-04
|
LAIK PAKAI
PREVENTIVE MAINTENANCE
|
TIDAK | Ready to Use |
||
| 14 |
11 Nov 2026
Anton Diki W
|
GSU-04
CIGADING 1
|
Pengukuran suhu ruang panel elektrik GSU-04
|
LAIK PAKAI
PREVENTIVE MAINTENANCE
|
TIDAK | Ready to Use |
||
| 15 |
11 Nov 2026
Anton Diki W
|
GSU-04
CIGADING 1
|
Lubrikasi roll festune cabin operator GSU 04
|
LAIK PAKAI
PREVENTIVE MAINTENANCE
|
TIDAK | Ready to Use |
||
| 16 |
11 Nov 2026
Anton Diki W
|
GSU-04
CIGADING 1
|
Grounding di area Motor creeper gantry tidak terpasang GSU 04
|
LAIK PAKAI
PREVENTIVE MAINTENANCE
|
PANTAU | Ready to Use |
||
| 17 |
11 Nov 2026
Anton Diki W
|
GSU-04
CIGADING 1
|
Motor creeper gantry GSU 04 tidak terpasang 2pcs, 1pcs sebelah laut dan 1pcs sebelah darat
|
RUSAK RINGAN
PREVENTIVE MAINTENANCE
|
PANTAU | Ready to Use |
||
| 18 |
11 Nov 2026
Anton Diki W
|
GSU-04
CIGADING 1
|
Cleaning motor powerpack gate feeder GSU 04
|
LAIK PAKAI
PREVENTIVE MAINTENANCE
|
TIDAK | Ready to Use |
||
| 19 |
28 Oct 2026
Anton Diki W
|
GSU-04
CIGADING 1
|
Pengukuran jalur input zerospeed GSU-04 sistem 2 PBCN 02 (hasil ok)
|
LAIK PAKAI
PREVENTIVE MAINTENANCE
|
TIDAK | Ready to Use |
||
| 20 |
28 Oct 2026
Hasyim Alhabsyi
|
GSU-04
CIGADING 1
|
Grounding area Motor creeper gantry sebelah laut hilang, rekues pasang
|
RUSAK RINGAN
REQUEST PENAMBAHAN
|
PANTAU 130000019654 |
In Process |
||
| 21 |
28 Oct 2026
Hasyim Alhabsyi
|
GSU-04
CIGADING 1
|
Motor creeper gantry tidak terpasang 3 pcs, rekues pasang
|
RUSAK RINGAN
PREVENTIVE MAINTENANCE
|
TIDAK | Ready to Use |
||
| 22 |
28 Oct 2026
Hasyim Alhabsyi
|
GSU-04
CIGADING 1
|
Cleaning motor powerpack belt feeder hopper GSU-04
|
LAIK PAKAI
PREVENTIVE MAINTENANCE
|
TIDAK | Ready to Use |
||
| 23 |
28 Oct 2026
Hasyim Alhabsyi
|
GSU-04
CIGADING 1
|
Cleaning dan lubrikasi zerospeed sistem 1 dan 2 di GSU-04
|
LAIK PAKAI
PREVENTIVE MAINTENANCE
|
TIDAK | Ready to Use |
||
| 24 |
12 Oct 2026
Anton Diki W
|
GSU-04
CIGADING 1
|
Lubrikasi roll festune cabin operator GSU 04
|
LAIK PAKAI
PREVENTIVE MAINTENANCE
|
TIDAK | Ready to Use |
||
| 25 |
12 Oct 2026
Hasyim Alhabsyi
|
GSU-04
CIGADING 1
|
Lubrikasi motor creeper brake gantry sisi laut dan darat.
|
LAIK PAKAI
PREVENTIVE MAINTENANCE
|
TIDAK | Ready to Use |
||
| 26 |
30 Sep 2026
Hasyim Alhabsyi
|
GSU-04
CIGADING 1
|
Kontaktor brake trolley pong sebelah laut nomor 1 pcs, Rekues ganti GSU-04
|
LAIK PAKAI
REQUEST GANTI
|
Medium 130000019073 |
Completed |
||
| 27 |
30 Sep 2026
Hasyim Alhabsyi
|
GSU-04
CIGADING 1
|
Kontaktor brake holding pong. Panel nomor 2 sebelah anyer
|
LAIK PAKAI
REQUEST GANTI
|
Medium 130000019070 |
Completed |
||
| 28 |
30 Sep 2026
Hasyim Alhabsyi
|
GSU-04
CIGADING 1
|
Kontaktor brake holding pong 2 pcs dan ada indikasi terbakar. Panel sebelah anyer nomor 1
|
RELEASE
REQUEST GANTI
|
Medium | Completed |
||
| 29 |
23 Sep 2026
Hasyim Alhabsyi
|
GSU-04
CIGADING 1
|
Inspeksi dan Pengukuran suhu ruang panel elektrik GSU-04 : 28.9°C
|
LAIK PAKAI
PREVENTIVE MAINTENANCE
|
TIDAK | Ready to Use |
||
| 30 |
23 Sep 2026
Hasyim Alhabsyi
|
GSU-04
CIGADING 1
|
Inspeksi dan Pengukuran suhu panel Closing GSU-04 : 27.7°C
|
LAIK PAKAI
PREVENTIVE MAINTENANCE
|
TIDAK | Ready to Use |
||
| 31 |
23 Sep 2026
Hasyim Alhabsyi
|
GSU-04
CIGADING 1
|
Inspeksi dan Pengukuran suhu panel Holding inverter GSU-04 : 32.7°C
|
LAIK PAKAI
PREVENTIVE MAINTENANCE
|
TIDAK | Ready to Use |
||
| 32 |
23 Sep 2026
Hasyim Alhabsyi
|
GSU-04
CIGADING 1
|
Inspeksi dan Pengukuran suhu panel Gantry GSU-04 : 29.2°C
|
LAIK PAKAI
PREVENTIVE MAINTENANCE
|
TIDAK | Ready to Use |
||
| 33 |
23 Sep 2026
Anton Diki W
|
GSU-04
CIGADING 1
|
Lidah kontaktor coil brake trolley pong 1pcs ( kontaktor sebelah laut ) GSU 04, request ganti
|
RELEASE
REQUEST GANTI
|
Medium 130000019073 |
Completed |
||
| 34 |
23 Sep 2026
Anton Diki W
|
GSU-04
CIGADING 1
|
Lidah kontaktor coil brake closing pong 1pcs ( sebelah merak panel no 01 ) GSU 04, request ganti
|
RELEASE
REQUEST GANTI
|
Medium 130000019071 |
Completed |
||
| 35 |
23 Sep 2026
Anton Diki W
|
GSU-04
CIGADING 1
|
Lidah kontaktor coil brake holding pong 2pcs ( panel sebelah anyer no. 01 dan no. 02 ) GSU 04, request ganti
|
RELEASE
REQUEST GANTI
|
Medium 130000019070 |
Completed |
||
| 36 |
07 Sep 2026
Anton Diki W
|
GSU-04
CIGADING 1
|
Lampu indikator running di panel gate powerpack GSU-04 tidak terpasang
|
RELEASE
REQUEST GANTI
|
Medium | Completed |
||
| 37 |
07 Sep 2026
Anton Diki W
|
GSU-04
CIGADING 1
|
Cleaning dan Penggantian filter motor fan holding closing trolley GSU-04 before dan after
|
LAIK PAKAI
PREVENTIVE MAINTENANCE
|
TIDAK | Ready to Use |
||
| 38 |
07 Sep 2026
Anton Diki W
|
GSU-04
CIGADING 1
|
Pengecekkan lidah kontaktor holding closing trolley GSU-04 (kondisi kontaktor ok)
|
LAIK PAKAI
PREVENTIVE MAINTENANCE
|
TIDAK | Ready to Use |
||
| 39 |
07 Sep 2026
Anton Diki W
|
GSU-04
CIGADING 1
|
Cleaning dan lubrikasi zerospeed GSU-04
|
LAIK PAKAI
PREVENTIVE MAINTENANCE
|
TIDAK | Ready to Use |
||
| 40 |
07 Sep 2026
Anton Diki W
|
GSU-04
CIGADING 1
|
Cleaning motor gate power pack dan panel gate powerpack GSU-04
|
LAIK PAKAI
PREVENTIVE MAINTENANCE
|
TIDAK | Ready to Use |
||
| 41 |
31 Aug 2026
Hasyim Alhabsyi
|
GSU-04
CIGADING 1
|
Inspeksi dan Pengukuran suhu ruang panel elektrik GSU-04 : 30.7°C
|
LAIK PAKAI
PREVENTIVE MAINTENANCE
|
TIDAK | Ready to Use |
||
| 42 |
31 Aug 2026
Hasyim Alhabsyi
|
GSU-04
CIGADING 1
|
Inspeksi dan Pengukuran suhu panel Closing GSU-04 : 28.1°C
|
LAIK PAKAI
PREVENTIVE MAINTENANCE
|
TIDAK | Ready to Use |
||
| 43 |
31 Aug 2026
Hasyim Alhabsyi
|
GSU-04
CIGADING 1
|
Inspeksi dan Pengukuran suhu panel Holding inverter GSU-04 : 27.3°C
|
LAIK PAKAI
PREVENTIVE MAINTENANCE
|
TIDAK | Ready to Use |
||
| 44 |
31 Aug 2026
Hasyim Alhabsyi
|
GSU-04
CIGADING 1
|
Inspeksi dan Pengukuran suhu panel Gantry GSU-04 : 26.2°C
|
LAIK PAKAI
PREVENTIVE MAINTENANCE
|
TIDAK | Ready to Use |
||
| 45 |
31 Aug 2026
Anton Diki W
|
GSU-04
CIGADING 1
|
Pengukuran suhu motor Gsu-04
Holding Drive 53 Bearing 41 Fan 44 Closing Drive 57 Bearing 42 Fan 46 Trolley Drive 49 Bearing 42 Fan 45 Suhu Motor belt feeder GSU 04 Motor 01 Drive 32 |
LAIK PAKAI
PREVENTIVE MAINTENANCE
|
TIDAK | Ready to Use |
||
| 46 |
31 Aug 2026
Anton Diki W
|
GSU-04
CIGADING 1
|
Bearing roll festune lepas 4 pcs GSU-04, bagian anyer
rekues ganti |
RELEASE
REQUEST GANTI
|
Medium 130000018835 |
Completed |
||
| 47 |
31 Aug 2026
Anton Diki W
|
GSU-04
CIGADING 1
|
Sling safety komunikasi putus di GSU 04 sebelah darat, req ganti
Sementara di vynil dan ( sudah di infokan ke elektrik eksekutor ) |
RELEASE
REQUEST GANTI
|
Medium 130000018836 |
Completed |
||
| 48 |
01 Aug 2026
Anton Diki W
|
GSU-04
CIGADING 1
|
Program megger motor drive BOOM GSU-04 :
GROUND-GROUND pengukuran 0 Mohm, GROUND-POSITIF, GROUND-NEGATIF hasil pengukuran 550Mohm POSITIF - NEGATIF hasil pengukuran 0 Mohm Exsitasi Ground F1 Ground F2 Hasil pengukuran 550Mohm |
LAIK PAKAI
PREVENTIVE MAINTENANCE
|
TIDAK | Ready to Use |
||
| 49 |
01 Aug 2026
Anton Diki W
|
GSU-04
CIGADING 1
|
Hasil Megger Motor cabel reel medium voltage GSU 04 :
U1 - G : 550 Mohm V1 - G : 550 Mohm W1 - G : 550 Mohm U2 - G : 550 Mohm V2 - G : 550 Mohm W2 - G : 550 Mohm Antar Phase U1 - U2 : 0 Mohm U1 - V2 : 550 Mohm U1 - W2 : 550 Mohm V1 - V2 : 0 Mohm V1 - U2 : 550 Mohm V1 - W2 : 550 Mohm W1 - W2 : 0 Mohm W1 - U2 : 550 Mohm W1 - V2 : 550 Mohm |
LAIK PAKAI
PREVENTIVE MAINTENANCE
|
TIDAK | Ready to Use |
||
| 50 |
01 Aug 2026
Anton Diki W
|
GSU-04
CIGADING 1
|
Cleaning dan Penggantian filter motor fan holding closing trolley GSU-04 before dan after
|
LAIK PAKAI
PREVENTIVE MAINTENANCE
|
TIDAK | Ready to Use |
||
| 51 |
25 Jul 2026
Hasyim Alhabsyi
|
GSU-04
CIGADING 1
|
Inspeksi dan Pengukuran suhu ruang panel elektrik GSU-04 : 32.2°C
|
LAIK PAKAI
PREVENTIVE MAINTENANCE
|
TIDAK | Ready to Use |
||
| 52 |
25 Jul 2026
Hasyim Alhabsyi
|
GSU-04
CIGADING 1
|
Inspeksi dan Pengukuran suhu panel Closing GSU-04 : 28.4°C
|
LAIK PAKAI
PREVENTIVE MAINTENANCE
|
TIDAK | Ready to Use |
||
| 53 |
25 Jul 2026
Hasyim Alhabsyi
|
GSU-04
CIGADING 1
|
Inspeksi dan Pengukuran suhu panel Holding inverter GSU-04 : 30.5°C
|
LAIK PAKAI
PREVENTIVE MAINTENANCE
|
TIDAK | Ready to Use |
||
| 54 |
25 Jul 2026
Hasyim Alhabsyi
|
GSU-04
CIGADING 1
|
Inspeksi dan Pengukuran suhu panel Gantry GSU-04 : 26.7°C
|
LAIK PAKAI
PREVENTIVE MAINTENANCE
|
TIDAK | Ready to Use |
||
| 55 |
08 Jul 2026
Hasyim Alhabsyi
|
GSU-04
CIGADING 1
|
Lubrikasi roll festun cabin operator GSU-04
|
LAIK PAKAI
PREVENTIVE MAINTENANCE
|
TIDAK | Ready to Use |
||
| 56 |
08 Jul 2026
Hasyim Alhabsyi
|
GSU-04
CIGADING 1
|
Cleaning motor power pack
|
LAIK PAKAI
PREVENTIVE MAINTENANCE
|
TIDAK | Ready to Use |
||
| 57 |
08 Jul 2026
Hasyim Alhabsyi
|
GSU-04
CIGADING 1
|
Motor trastle brake tidak terpasang 2 pcs di sisi merak darat dan merak laut. Req. Pasangkan
|
RUSAK RINGAN
REQUEST REPAIR
|
Medium 130000017501 |
In Process |
||
| 58 |
17 Jun 2026
Hasyim Alhabsyi
|
GSU-04
CIGADING 1
|
Program megger motor drive TROLLEY GSU-04 :
Antar Phase GROUND - GROUND = 0 MOhm, GROUND - POSITIF = 550 MOhm GROUND - NEGATIF = 550 MOhm POSITIF - NEGATIF = 0 MOhm Exsitasi Ground - F1 : 550 MOhm Ground - F2 : 550 MOhm Kode Motor : M6 |
LAIK PAKAI
PREVENTIVE MAINTENANCE
|
TIDAK | Ready to Use |
||
| 59 |
13 Jun 2026
Hasyim Alhabsyi
|
GSU-04
CIGADING 1
|
Inspeksi dan Pengukuran suhu ruang panel elektrik GSU-04 : 27.3°C
|
LAIK PAKAI
PREVENTIVE MAINTENANCE
|
TIDAK | Ready to Use |
||
| 60 |
13 Jun 2026
Hasyim Alhabsyi
|
GSU-04
CIGADING 1
|
Inspeksi dan Pengukuran suhu panel Closing GSU-04 : 38.8°C
|
LAIK PAKAI
PREVENTIVE MAINTENANCE
|
TIDAK | Ready to Use |
||
| 61 |
13 Jun 2026
Hasyim Alhabsyi
|
GSU-04
CIGADING 1
|
Inspeksi dan Pengukuran suhu panel Holding inverter GSU-04 : 31.2°C
|
LAIK PAKAI
PREVENTIVE MAINTENANCE
|
TIDAK | Ready to Use |
||
| 62 |
13 Jun 2026
Hasyim Alhabsyi
|
GSU-04
CIGADING 1
|
Inspeksi dan Pengukuran suhu panel Gantry GSU-04 : 26.9°C
|
LAIK PAKAI
PREVENTIVE MAINTENANCE
|
TIDAK | Ready to Use |
||
| 63 |
13 Jun 2026
Hasyim Alhabsyi
|
GSU-04
CIGADING 1
|
Cleaning dan Penggantian filter motor fan holding closing trolley GSU-04 (dokumentasi before dan after)
|
LAIK PAKAI
PREVENTIVE MAINTENANCE
|
TIDAK | Ready to Use |
||
| 64 |
13 Jun 2026
Hasyim Alhabsyi
|
GSU-04
CIGADING 1
|
Program megger motor drive HOLDING GSU-04 :
Antar Phase GROUND - GROUND = 0 MOhm, GROUND - POSITIF = 46 MOhm GROUND - NEGATIF = 47 MOhm POSITIF - NEGATIF = 0 MOhm Exsitasi Ground - F1 : 550 MOhm Ground - F2 : 550 MOhm Pantau berkala Kode Motor : M4 |
LAIK PAKAI
PREVENTIVE MAINTENANCE
|
PANTAU | Ready to Use |
||
| 65 |
13 Jun 2026
Hasyim Alhabsyi
|
GSU-04
CIGADING 1
|
Program megger motor drive CLOSING GSU-04 :
Antar Phase GROUND - GROUND = 0 MOhm, GROUND - POSITIF = 24 MOhm GROUND - NEGATIF = 24 Mohm POSITIF - NEGATIF = 0 MOhm Exsitasi Ground - F1 : 550 MOhm Ground - F2 : 550 MOhm Request Service Kode Motor : M5 |
RELEASE
REQUEST SERVICE
|
Medium 130000018329 |
Completed |
||
| 66 |
14 May 2026
Hasyim Alhabsyi
|
GSU-04
CIGADING 1
|
Inspeksi dan Pengukuran suhu ruang panel elektrik GSU-04 : 29.3°C
|
LAIK PAKAI
PREVENTIVE MAINTENANCE
|
TIDAK | Ready to Use |
||
| 67 |
14 May 2026
Hasyim Alhabsyi
|
GSU-04
CIGADING 1
|
Inspeksi dan Pengukuran suhu panel Closing GSU-04 : 27.0°C
|
LAIK PAKAI
PREVENTIVE MAINTENANCE
|
TIDAK | Ready to Use |
||
| 68 |
14 May 2026
Hasyim Alhabsyi
|
GSU-04
CIGADING 1
|
Inspeksi dan Pengukuran suhu panel Holding inverter GSU-04 : 25.8°C
|
LAIK PAKAI
PREVENTIVE MAINTENANCE
|
TIDAK | Ready to Use |
||
| 69 |
14 May 2026
Hasyim Alhabsyi
|
GSU-04
CIGADING 1
|
Inspeksi dan Pengukuran suhu panel Gantry GSU-04 : 26.3°C
|
LAIK PAKAI
PREVENTIVE MAINTENANCE
|
TIDAK | Ready to Use |
||
| 70 |
14 May 2026
Hasyim Alhabsyi
|
GSU-04
CIGADING 1
|
Konekan Motor gantry ditemukan lepas 1 pcs (akan dilakukan program megger)
|
LAIK PAKAI
PREVENTIVE MAINTENANCE
|
PANTAU | Ready to Use |
||
| 71 |
14 May 2026
Hasyim Alhabsyi
|
GSU-04
CIGADING 1
|
Motor Eldo brake tidak terpasang di sebelah laut-anyer dan Limit Switch Rusak, Request Perbaiki
|
RUSAK RINGAN
REQUEST REPAIR
|
Medium 130000017501 |
In Process |
||
| 72 |
14 May 2026
Hasyim Alhabsyi
|
GSU-04
CIGADING 1
|
Motor Eldo brake tidak terpasang di sebelah darat-anyer dan Limit Switch Rusak, Request Perbaiki
|
RUSAK RINGAN
REQUEST REPAIR
|
Medium 130000017501 |
In Process |
||
| 73 |
14 May 2026
Hasyim Alhabsyi
|
GSU-04
CIGADING 1
|
Lampu LED Desk Control 24 VDC mati sebanyak 3 pcs, Request ganti
|
RELEASE
REQUEST GANTI
|
Medium 130000018124 |
Completed |
||
| 74 |
14 May 2026
Hasyim Alhabsyi
|
GSU-04
CIGADING 1
|
Penggantian filter fan motor holding, clossing, dan trolley GSU-04 (dokumentasi before dan after)
|
LAIK PAKAI
PREVENTIVE MAINTENANCE
|
TIDAK | Ready to Use |
||
| 75 |
04 May 2026
Anton Diki W
|
GSU-04
CIGADING 1
|
Pengukuran suhu motor Gsu-04
Holding Drive 52 Bearing 45 Fan 43 Closing Drive 56 Bearing 42 Fan 48 Trolley Drive 60 Bearing 41 Fan 46 Suhu Motor belt feeder GSU 04 Motor 01 Drive 37 |
LAIK PAKAI
PREVENTIVE MAINTENANCE
|
TIDAK | Ready to Use |
||
| 76 |
04 May 2026
Anton Diki W
|
GSU-04
CIGADING 1
|
Penggantian filter motor fan holding closing trolley GSU-04
|
LAIK PAKAI
PREVENTIVE MAINTENANCE
|
TIDAK | Ready to Use |
||
| 77 |
18 Apr 2026
Hasyim Alhabsyi
|
GSU-04
CIGADING 1
|
Inspeksi dan Pengukuran suhu ruang panel elektrik GSU-04 : 28.2°C
|
LAIK PAKAI
PREVENTIVE MAINTENANCE
|
TIDAK | Ready to Use |
||
| 78 |
18 Apr 2026
Hasyim Alhabsyi
|
GSU-04
CIGADING 1
|
Inspeksi dan Pengukuran suhu panel Closing GSU-04 : 31.3°C
|
LAIK PAKAI
PREVENTIVE MAINTENANCE
|
TIDAK | Ready to Use |
||
| 79 |
18 Apr 2026
Hasyim Alhabsyi
|
GSU-04
CIGADING 1
|
Inspeksi dan Pengukuran suhu panel Holding inverter GSU-04 : 33.1°C
|
LAIK PAKAI
PREVENTIVE MAINTENANCE
|
TIDAK | Ready to Use |
||
| 80 |
18 Apr 2026
Hasyim Alhabsyi
|
GSU-04
CIGADING 1
|
Inspeksi dan Pengukuran suhu panel Gantry GSU-04 : 25.8°C
|
LAIK PAKAI
PREVENTIVE MAINTENANCE
|
TIDAK | Ready to Use |
||
| 81 |
18 Apr 2026
Hasyim Alhabsyi
|
GSU-04
CIGADING 1
|
Coupling motor kabel drum GSU-04 berkarat. Req. Service
|
RELEASE
REQUEST SERVICE
|
Medium 130000017930 |
Completed |
||
| 82 |
18 Apr 2026
Hasyim Alhabsyi
|
GSU-04
CIGADING 1
|
Cover fan motor kabel drum GSU-04 rusak dan korosi. Req. Ganti
|
RELEASE
REQUEST GANTI
|
Medium 130000017931 |
Completed |
||
| 83 |
18 Apr 2026
Hasyim Alhabsyi
|
GSU-04
CIGADING 1
|
Struktur kanopi panel LCS gantry GSU-04 rusak. Request Perbaikan
|
RELEASE
REQUEST REPAIR
|
Medium 130000018050 |
Completed |
||
| 84 |
18 Apr 2026
Hasyim Alhabsyi
|
GSU-04
CIGADING 1
|
Motor eldo brake GSU-04 tidak ada 2 pcs (1 darat merak, 1 laut merak)
|
RUSAK RINGAN
REQUEST PENAMBAHAN
|
Medium 130000017501 |
In Process |
||
| 85 |
18 Apr 2026
Hasyim Alhabsyi
|
GSU-04
CIGADING 1
|
Atap / Plavon ruang panel terlihat bekas bocor di GSU-04, req. Pantau
|
RUSAK RINGAN
PREVENTIVE MAINTENANCE
|
PANTAU | Ready to Use |
||
| 86 |
18 Apr 2026
Anton Diki W
|
GSU-04
CIGADING 1
|
Roll pendulum kabel drum di GSU-04 sebanyak 6 pcs macet di sebelah merak. Request Repair
|
RELEASE
REQUEST REPAIR
|
Medium 130000017924 |
Completed |
||
| 87 |
18 Apr 2026
Hasyim Alhabsyi
|
GSU-04
CIGADING 1
|
Lubrikasi roll festune cabin operator di GSU-04
|
LAIK PAKAI
PREVENTIVE MAINTENANCE
|
TIDAK | Ready to Use |
||
| 88 |
13 Apr 2026
Hasyim Alhabsyi
|
GSU-04
CIGADING 1
|
Lubrikasi roll festun cabin operator GSU-04
|
LAIK PAKAI
PREVENTIVE MAINTENANCE
|
TIDAK | Ready to Use |